Programming
5-14
Setup Group (continued)
[Ada
p
tive I Lim]
Parameter # 149 Factory Default “Enabled”
[Adaptive
I
Lim]
Parameter Type Read & Write
When ENABLED (default), this parameter allows tripless
commanded accelerations into medium to high inertia
conditions and delivers maximum performance when drive
load conditions change with time. For most circumstances
this is the correct selection.
When DISABLED, this parameter allows quicker
acceleration times from stopped to commanded speed with
low system inertia.
Units Text Settings “Enabled”