Installation/Wiring
2-19
Figure 2.7 TB2 Designations
[Input Mode] = “Three Wire” or [Input Mode]=“3 w/2nd Acc.”
Figure 2.8 TB2 Designations – Two Wire Control Operation
[Input Mode]=“Run Fwd/Rev” or [Input Mode]=“Run F/R 2nd A”
Remote Pot
1
2
3
4
5
6
7
8
9
10
Source
Momentary Input
Maintained Input
Wires must be shielded
Wiper or 0-10V DC Input
Common
4-20mA Input
0-10V Output
0-10V
Common
Stop
Start
Output #1
➀➃
24VDC Source
(User Supplied)
11
12
13
14
15
16
17
18
19
20
Enable
Common
Reverse
Jog
Common
Common
Shield
(connect to drive at TB2 Only)
SW2
SW3
SW1
(Sink)
Output #2
User Side
Remote Pot
Run Forward
Run Reverse
Jumper
➀➁
Jumper
➀➃
1
2
3
4
5
6
7
8
9
10
Source
Wiper or 0-10V DC Input
Common
4-20mA Input
0-10V Output
0-10V
Common
Stop
User Side
Start
Output #1
24VDC Source
(User Supplied)
11
12
13
14
15
16
17
18
19
20
Enable
Common
Reverse
Jog
Common
SW2
SW3
SW1
(Sink)
Output #2
See Table 2.F and
Notes on page 2-21
efesotomasyon.com - Allen Bradley,Rockwell,plc,servo,drive