EasyManuals Logo

Allen-Bradley LOGIX 5000 Programming Manual

Allen-Bradley LOGIX 5000
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Design a sequential function chart
Chapter 1
Rockwell Automation Publication 1756-PM006I-EN-P - February 2018 39
Use logic to clear data
Let the controller automatically clear data
Each option requires you to make these decisions.
Choose a last scan option.
Based on the last scan option, develop your logic so that the last scan returns
data to the correct values.
On the last scan of each step, you have these options. The option that you choose
applies to all the steps in all the SFCs in this controller.
If you want to And on the last scan of a step Then see
Control which data to clear Execute only P and P0 actions and use them to clear the
required data.
Use the don’t scan option on page 40
Execute all actions and use either of these options to clear the
required data.
Status bits of the step or action to condition logic
P and P0 actions
Use the programmatic reset option on page 41
Let the controller clear data ---------------------------------------------> Use the automatic reset option on page 43
The following table compares the different options for handling the last scan of a
step.
Choose a last scan option

Table of Contents

Other manuals for Allen-Bradley LOGIX 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley LOGIX 5000 and is the answer not in the manual?

Allen-Bradley LOGIX 5000 Specifications

General IconGeneral
BrandAllen-Bradley
ModelLOGIX 5000
CategoryController
LanguageEnglish

Related product manuals