Dismantling
DANGER!
Danger of fatal injury due to electric current!
Electrical connections may be installed only by qualied
electricians.
Before opening the unit, disconnect the system from the
power supply and secure it from being switched back
on!
REMOVAL OF THE BUFFER BATTERY
ATTENTION
Before scrapping the heating and heat pump regulator, re-
move the buer battery on the main board. You can use
a screwdriver to remove the battery from its bracket. Dis-
pose of battery and electronic components in keeping
with environmental considerations.
Softwareupdate
A software version < V2.63 must no longer be loaded on a unit
(only LWD... and SWP371-SWP691 and SWP291H-SWP561H) with
software version ≥V2.63..
Output-controlled air/water heat pumps may only be operated
with software version V3.xx and higher..
Commissioning / Switching on
for the rst time
When switched on for the rst time the language selection ap-
pears rst.
Select the display language: part 1 of the conroller
manual, section “Basis information on the operation“.
You see:
When the heat pump is switched on for the rst time the
above display appears.
The display always appears when the controller is swit-
ched on or on changing to the standards menu. This
screen is no longer displayed if the heat pump or ZWE1
has more than 10 operating hours.
No ZWE (second heat generator) is released by the controller until
the display is conrmed with OK.
NOTICE
No heat generator runs during a cold start of air/water heat
pumps.
ATTENTION
The unit can be damaged if the display is conrmed with
OK, although the system is not properly lled.
On switching on the controller voltage, under certain circum-
stances the following is displayed:
After deleting this display the unit can be operated properly.
Otherwise test the 3 pole cable for the BUS connection.
The following display then appears:
NOTICE
The heating phase until the compressor starts can take se-
veral hours when starting up air/water heat pumps for the
rst time.

Table of Contents

Other manuals for Alpha-InnoTec Luxtronik

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec Luxtronik and is the answer not in the manual?

Alpha-InnoTec Luxtronik Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLuxtronik
CategoryController
LanguageEnglish

Related product manuals