Silent Mode Week =
Three time periods can be
entered for the whole week.
5 + 2 =
Three time periods can be entered for
Monday to Friday
Day =
Three time periods can be entered for
exact times of day
The set time is noise-reduced mode.
HOT GAS UTILISATION, ONLY LWP
Higher temperatures of up to 75°C are available with hot gas utili-
sation. The temperature is not always guaranteed. The heat pump
must already be in operation due to another requirement.
The heat pump will switch o with a desuperheater temperature
of 80°C.
The recirculation pump will be actuated every 30 minutes for 30
seconds with a hot gas temperature higher than 85°C
CAUTION!
Injuries caused by hot temperatures!
Very high temperatures can occur on the desuperhea-
ter and the pipework for the hot gas utilisation when the
hot gas utilisation is in operation. Any contact can lead
to burns. Never touch the desuperheater or pipework
when in operation or afterwards
The hot gas utilisation is set to “Yes” as default.
If hot gas utilisation is not used, then this must be set to “No” un-
der system settings.
1. switch of the desuperheater:
2. Is the desuperheater switched on, you can x the temperature
Here you can y the temperature of the desuperhea-
ter from 30°C to 75°C.
You can switch the desuperheater on and o:
Desuperheater
Desuperheater max.