EasyManua.ls Logo

Alpha AS100 Series - Page 89

Alpha AS100 Series
179 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter VI Specified Function Introduction
88
setting
value
Up-down
Count Pulse Edge
Ops
Inverse of input
pulse level
Side-mode
Type of CNC
0
0 positive edge
0 unchanged
0 General
system
1
0 positive edge
0 unchanged
1 Siemens
system
2
0 positive edge
1 negative
0 General
system
3
0 positive edge
1 negative
1 Siemens
system
4
1 negative edge
0 unchanged
0 General
system
5
1 negative edge
0 unchanged
1 Siemens
system
6
1 negative edge
1 negative
0 General
system
7
1 negative edge
1 negative
1 Siemens
system
Normally, choosing the general system could be suitable for pulse form of most
numerical control system, while the Siemens system is only for some models of
Siemens numerical control system.
Function
Code
Parameter
Name
Attribute
Setting
Range
Unit
Factory
Defaults
P00.16
Parameter
initialization
Power up
effective
0~2
-
0
Function Description:
0: No operation
1: All parameters except parameters of servo motor are initialized to their default
values. Set the parameters to 1 and press confirm button. Then the system will begin to
restore its default value. The LED is showing ‘start’ at first, when it’s turning
into ’done’, the operation has been successfully completed and all the default values of

Table of Contents