Chapter II Installation and Wiring
38
2.10 Holding Brake Wiring
The power supply connection for the servo motor holding brake (mechanical brake) has
no polarity requirements, the DC power supply shall be provided by users.
The standard wiring for brake signal (BRK) outputted by the drive and the brake power
supply are shown in Fig. 2-17:
Fig. 2-18 Wiring Diagram of Brake
2.11 Wiring Precautions
Ensure the voltage rating of the power supply to be connected is proper.
Please do not connect the output ends U, V, and W of the servo drive with a
power supply.
Check the junction box after powering off for 5min to avoid electric shock.
Perform wiring according to the terminal voltage and polarity to avoid equipment
damage or personal injury.