Chapter VI Specified Function Introduction
96
Function
Code
Parameter Name
Attribute
Setting
Range
Unit
Factory
Defaults
P03.02
D03 function and
enabled status setting
Power up
effective
0~3
256~259
-
2
Function Description:
Refer to P03.00 for function description.
Function
Code
Parameter Name
Attribute
Setting
Range
Unit
Factory
Defaults
P03.03
DO4 function and
enabled status setting
Power up
effective
0~3
256~259
-
3
Function Description:
Refer to P03.00 for function description.
Function
Code
Parameter Name
Attribute
Setting
Range
Unit
Factory
Defaults
P03.04
DI1 function and
enabled status setting
Power up
effective
0~20
256~276
-
0
Function Description:
Setting of function and enabled status of digital input DI1. The setting value can be
obtained by adding enabled status settings and function setting together. If the setting
value is not in the setting range, the system will retain the last one.
Enabled status setting value:
0: Active High
256: Active Low
Setting Value of Input Function:
0: Servo Enabling (S-ON)
1: Alarm Reset (ALM-RST)
2: Negative Over-travel Limit
(N-OT)
3: Positive Over-travel Limit (P-OT)
4: Deviation Counter Reset (CLR)
5: Pulse Inhibit (PINH)
6: the second electronic gear ratio
(GEAR2)
7: Spare