Putting into operation
AMASPRAY+
BAG0017.7 10.17
23
Input of impulses per litre:
1. Actuate key .
the actual value is indicated.
2. Enter the value with keys
oer .
3. Confirm input with key
.
Determination of impulses per litre:
1. Fill the tank with water and weigh the machine.
and determine quantity of water added or
weigh the machine afterwards.
2. Simultaneously actuate the keys
and .
3. Switch on with the field sprayer stationary and spray out several
hundred of litres (the computer then counts the impulses at the
flow meter).
4. Determine the sprayed amount (re-weigh the machine).
5. Enter the value for the sprayed amount with the keys
or
.
6. Confirm input with key
.
AMASPRAY
+
has determined and stored the value "Impulses /
Litres" .
The impulse number of the flow meter has to be checked several
times over the year, especially prior to every season.