AMASPRAY+ BAG0017.7 10.17
5.6 Determination of impulses per litre of the flow meter (pre-set by the fac-
tory)
• The AMASPRAY
+
requires the calibration value "Im-
pulses per litre" for the flow meter
for determination and control of the spray rate [l/ha].
for the determination of the daily and total amount of
the sprayed spray cocktail [l].
In case the calibration figure is not known you have to de-
termine the calibration value "Impulses per litre" via a cali-
bration of the flow meter /return flow meter.
If the calibration figure is exactly known you can manually
enter the calibration value "Impulses per litre" for the flow
meter / return flow meter into the AMASPRAY
+
.
• For the accurate conversion of the spray rate in [l/ha] it is
necessary to determine the calibration value "Impulses per
litre" of the flow meter at least one a year.
As a matter of principle determine the calibration value "Im-
pulses per litre" of the flow meter:
after removal of the flow meter.
after a prolonged period of operation as there may be
deposits of spray agent residue may in the flow meter.
in case of deviations between the required and the ac-
tually applied spray rate [l/ha].