BAG0017.7 10.17
7 Faults
Fault
Spray rate is not correct
Pressure meter is defective
Contact an authorised workshop
Pressure regulation valve defec-
tive
Contact an authorised workshop
Spray pressure adjustment is not
possible
Power supply is interrupted
Pressure regulation valve defec-
tive
Contact an authorised workshop
Switching boom part width sec-
tions is not possible
Power supply is interrupted
Boom part width section valve
defective
Exchange the voom part width
section valve
No correct switching electric
boundary nozzles switching
Motor valves dirty / defect
• changing over from folding
to tilt adjustment
Hydraulic valves are dirty / defec-
tive
Exchange hydraulic valves
7.1 Alarm messages
Required value alarm
Spray rate not correct
• Wrong forward speed.
• Wrong spray nozzles.
Fill level alarm
The fill level drops below the en-
tered alarm limit
• Refill the tank.
Pressure alarm
Spray pressure below / over the
entered alarm limit
• Univ. joint shaft speed
too low / too high.