Spread rate check (determining the calibration factor)
28
AmaSpread+ BAG0126.4 09.17
8.3 Online calibration
The calibration value is continuously recalculated via online weighing
and the theoretically applied quantity. The required shutter position is
adjusted online.
: Select the Weighing / Online calibration menu.
Display in the Work menu: Online calibration active
Online calibration can only be started when the scale is at rest and
with hopper content greater than 200 kg.
If the
symbol appears on the display, the spreader is not at rest.
During the spreading work, online calibration will be switched off au-
tomatically when the hopper content drops below 200 kg!
Spreading will continue with the displayed calibration factor.
After filling (hopper volume greater than 200 kg), online calibration will
be restarted automatically!
When working on hilly terrain or if the ground conditions are not level,
system-induced fluctuations in determination of weight can occur
In this case switch off online calibration during the run.
Spreading will continue with the displayed calibration factor.