Faults
42
AmaSpread+ BAG0126.4 09.17
11 Faults
Error number
Symbol for fault
11.1 Alarms
An alarm appears if an error can lead to a hazard to the operator's
health.
Acoustic signal: 3 x tone signal for a duration of 3 seconds.
Error number: 005 Internal output error
The power supply is switched off immediately when the error is de-
tected.
11.2 Warnings
A warning appears when the implement cannot work properly or an
error poses a risk to the implement.
Acoustic signal: 1 x tone signal for a duration of 3 seconds.
Error number: 1 No SD card inserted
Error number: 2 Faulty communication with the internal storage
Error number: 3 Faulty data in the internal storage
Error number: 4 Temperature is too high
Error number: 5 Output overcurrent
Error number: 6 Setting motor left does not respond
Error number: 7 Setting motor right does not respond
Error number: 8 Hopper filling level too low,
minimum hopper content 500 k g
Error number: 9 Scales failed
Error number: 32 Limiter setting motor does not respond
Error number: 39 Shutter sensor left has failed
Error number: 40 Shutter sensor right has failed
Error number: 41 Limiter sensor failure