Faults
Cirrus 03 BAH0101-05 11.19
281
11.4 Fault table
Fault Possible cause Remedy
Track marker not changing Hydraulic valve jamming Replace the hydraulic valve
Tramline counter not working Stop key actuated Switch off the stop key
Working with the wrong tramline
rhythm
Set the correct tramline rhythm
on the control terminal
Working position sensor is
defective
Replace the working position
sensor
Alarm despite correct blower fan
speed
The wrong alarm limit is set Set the correct alarm limit
Oil volume too low or too high Set the oil volume
Fan sensor defective Replace the fan sensor