MONITOR PANEL
Erroneous tank level indications can be caused by:
Water
with
low
mineral
co~tent.
The leveiis measured
by
a very low level
electrical signal traveling through the liquid.
Some water may not conduct the
signal properly. This condition may be infrequent, but can exist. Check the
panel reading when the fresh water tank
is
filled.
Material
trapped
on
the
sides
of
the
holding
tanks
may
give a full reading
when
the tank is actually empty.
NOTE:
If
the sensor probes mounted in the
tanksget
coated
with grease, the
monitor
panel
may
indicate falsely
or
not
at
all.
Avoid
pouring grease, oils
or
similar substances down
drains
or
the toilet.
If
this is unavoidable, the holding tank(s)
should
be
washed
outwith
a
soapy
water solution. See
your
dealer for additional information.
ELECTRICAL MONITOR PANEL
r;--
..
CJ
o GOOD
C)
MAIN
o
FAIR.
BATTERY
o LOW
.
CHECK
C)
o CHARGING
SOLAR
C)
AUX'
,
CHARGER
o CHARGED
Electrical Monitor Panel
\
-'
The chassis batteries are identified as the
MAIN
BATTERY and the coach
batteries are identified as the
AUX BATTERY. The solar charging system
is
identified as
SOLAR
CHARGER.