Maintenance | 6-7
30
141
r
float
ANAOUT2
135
2
CurrentOutput2-
142
rw
float
ANAOUT2O
137
2
CurrentOutput2Offset-
143
rw
uint16
ANAOUT2P
139
1
CurrentOutput2Parameter-
144
rw
float
ANAOUT2S
140
2
CurrentOutput2Span-
145
rw
int16
ANAOUT2T
142
1
CurrentOutput2OutputType.0=4-
20 mode, 1=0-20 mode.
Ifoverangeenable(ANAOUT2OR=
1)
0 = 3.78 - 20.5, 1 = 0-20.5, high or
low values can also be set by fault
value,SeeFaultoption(ANAOUT2F)
-
146
rw
uint16
ANAOUT2OR
143
1
CurrentOutput2 OverrangeEnable.
0=disabled, 1=enabled
147
rw
uint16
ANAOUT2F
144
1
CurrentOutput2FaultOption.0=No
fault,1=Lowfault,2=Highfault.
Ifhighfault(2):
Highendofrangebecomes22mA
Outputratiobecomes1
Iflowfault(1)ANDin4-20 mode
(ANAOUT2T=0):
Lowendofrangebecomes3mA
Outputratiobecomes0.
148
r
uint16
RELAY1
145
1
Relay1.0=OPEN,1=CLOSED
149
rw
uint16
RELAY1D
146
1
Relay1Delay.Holdstherelayoutput
for this set amount of time.
150
rw
uint16
RELAY1F
147
1
Relay1Function.0=Disabled,
1=Concentration, 3=Data Valid,
4=System alarm
151
rw
uint16
RELAY1S
148
1
Relay1Source.Thesource
parameter number used to evaluated
the relay function.
152
rw
float
RELAY1V
149
2
Relay1Value.Thevalueusedto
evaluate the relay function.
153
r
uint16
RELAY2
151
1
Relay2.0=OPEN,1=CLOSED
154
rw
uint16
RELAY2D
152
1
Relay2Delay.Holdstherelayoutput
for this set amount of time.
155
rw
uint16
RELAY2F
153
1
Relay2Function.0=Disabled,
1=Concentration, 3=Data Valid,
4=System alarm
156
rw
uint16
RELAY2S
154
1
Relay2Source.Thesource
parameter number used to evaluated
the relay function.
157
rw
float
RELAY2V
155
2
Relay2Value.Thevalueusedto
evaluate the relay function.
158
r
uint16
RELAY3
157
1
Relay3.0=OPEN,1=CLOSED
159
rw
uint16
RELAY3D
158
1
Relay3Delay.Holdstherelayoutput
for this set amount of time.
160
rw
uint16
RELAY3F
159
1
Relay3Function.0=Disabled,
1=Concentration, 3=Data Valid,
4=System alarm
161
rw
uint16
RELAY3S
160
1
Relay3Source.Thesource
parameter number used to evaluated
the relay function.
162
rw
float
RELAY3V
161
2
Relay3Value.Thevalueusedto
evaluate the relay function.
163
r
uint16
RELAY4
163
1
Relay4.0=OPEN,1=CLOSED
31
164
rw
uint16
RELAY4D
164
1
Relay4Delay.Holdstherelayoutput
for this set amount of time.
165
rw
uint16
RELAY4F
165
1
Relay4Function.0=Disabled,
1=Concentration, 3=Data Valid,
4=System alarm
166
rw
uint16
RELAY4S
166
1
Relay4Source.Thesource
parameter number used to evaluated
the relay function.
167
rw
float
RELAY4V
167
2
Relay4Value.Thevalueusedto
evaluate the relay function.
168
rwf
boolean
RELAYENA
169
1
Master enable for all relays.
0=Disabled,1=Enabled
169
rwf
char[20]
ALYTE1
170
10
Analyte1Name
170
r
float
ALYTE1CON
180
2
Analyte1Concentration
171
rw
float
CONCLIMITH1
182
2
Analyte1bandhighlimiteband1
172
rw
float
CONCLIMITL1
184
2
Analyte1bandlowlimiteband1
173
rw
float
CONCLIMITH2
186
2
Analyte1band high limite band 2
174
rw
float
CONCLIMITL2
188
2
Analyte1bandlowlimiteband2
175
rw
float
CONCLIMITH3
190
2
Analyte1bandhighlimiteband3
176
rw
float
CONCLIMITL3
192
2
Analyte1bandlowlimiteband3
177
rw
float
CONCLIMITH4
194
2
Analyte1bandhighlimiteband4
178
rw
float
CONCLIMITL4
196
2
Analyte1bandlowlimiteband4
179
rwf
char[20]
ALYTE2
198
10
Analyte2Name
180
r
float
ALYTE2CON
208
2
Analyte2Concentration
181
r
float
TECTEMP
210
2
TECTemperatureValue
182
rwf
int16
TECAT
212
1
HeaterActuatorType.0=Reverse,
1=Forward.
183
rwf
float
TECDEVT
213
2
Heater Deviation Tolerance. Ignored if
0.Otherwisehighorlowlimitalarm
are set when value is out bounds of 1
deviation
184
rwf
float
TECDT
215
2
Heater Deriviative Time
185
r
float
TECHDC
217
2
Heater Duty Cycle
186
rwf
float
TECIT
219
2
Heater Integral Time
187
rwf
float
TECPB
221
2
Heater Proportional Band
188
rwf
float
TECSP
223
2
Heater Set Point
189
rwf
float
TECST
225
2
TECSampleTime
190
rwf
float
TECHYS
227
2
TEChysterisi
191
r
float
ELECTEMP
229
2
ElectronicsTemperature
192
r
float
CELLTEMP
231
2
CellRTD1Filteredvalue
193
rwf
float
CELLSP
233
2
Cell Set Point
194
rwf
float
CELLDEVT
235
2
Cell Deviation Tolerance. Ignored if 0.
Otherwisehighorlowlimitalarmare
set when value is out bounds of 1
deviation
195
rwf
float
NORMTEMP
237
2
Calibration temperature for
concentration compensation.
196
rwf
float
NORMPRES
239
2
Calibration pressure for concentration
compensation
197
rwf
float
MAXTEMP
241
2
MaxTECtemperature
198
rwf
float
MINTEMP
243
2
MinTECtemperature
199
rw
uint
LOGSAVEINT
245
2
Interval in minutes to save the log
data
200
rw
char[10]
CONCUNIT2
247
5
Concentration Unit of Measure for
analyte 2
201
rw
uint
ALYTE1RES
252
2
Decimal places to use for displaying
analyte 1

Table of Contents