6-18 | Model 5100 HD Analyzer
Relay2Delay.Holdstherelayoutputforthis
set amount of time.
Relay2Function.0=Disabled,
1=Concentration, 3=Data Valid, 4=System
alarm
Relay2Source.Thesourceparameter
number used to evaluated the relay function.
Relay2Value.Thevalueusedtoevaluate
the relay function.
Relay3.0=OPEN,1=CLOSED
Relay3Delay.Holdstherelayoutputforthis
set amount of time.
Relay3Function.0=Disabled,
1=Concentration, 3=Data Valid, 4=System
alarm
Relay3Source.Thesourceparameter
number used to evaluated the relay function.
Relay3Value.Thevalueusedtoevaluate
the relay function.
Relay4.0=OPEN,1=CLOSED
Relay4Delay.Holdstherelayoutputforthis
set amount of time.
Relay4Function.0=Disabled,
1=Concentration, 3=Data Valid, 4=System
Relay4Source.Thesourceparameter
number used to evaluated the relay function.
Relay4Value.Thevalueusedtoevaluate
the relay function.
Master enable for all relays. 0=Disabled,
1=Enabled
Concentration Unit of Measure for analyte 2
Decimal places to use for displaying analyte 1
Decimal places to use for displaying analyte 2
Normally closed indicator for relay 1.
1=Normally closed, 0=Normally open
Normally closed indicator for relay 2.
1=Normally closed, 0=Normally open
Normally closed indicator for relay 3.
1=Normally closed, 0=Normally open
Normally closed indicator for relay 4.
1=Normally closed, 0=Normally open
Temporary cache to miror warnings in
SYSALARM1
Temporary cache to miror warnings in
SYSALARM2
ConcentrationofReferencecall
Analogoutput1,0- follow source during cal,
1 - hold output during cal
Analogoutput2,0- follow source during cal,
1 - holdoutputduringcalL82
Referenceconcentration of the reference cell
at
ifFALSE,usestaticpressure
Max Pressure allowed in PPMV to Dew Point
Min Pressure allowed in PPMV to Dew Point
Referenceconcentrationalarmband(%)
Referenceconcentrationalarmband2(%)
Background compensation factor
Background compensation temperature
UserAnalogInput1output(engrunits)
UserAnalogInputFixedSubstituteValue
CellRTD1IIRFilterWeight
RTD2(referencecelltemperature)
Unclamped analyte 1 concentration value
Unclamped analyte 2 concentration value
PRESX1AnalogInput Filtered value
ConcentrationofReferencecall
Analyte1Concentrationinotherunit
2nd Concentration Unit of Measure for
analyte 1
Data Valid. 0=Not Valid, 1=Valid
0=Line-lock mode, 1=Sample, 2=Calib
Referencetemperatureforthisdiode
Autocalibration.0=disabled,1=enabled.
0=Zero+Span, 1=Zero, 2=Span
The last day that the calibration was triggered
by the scheduler
1=perform autocal immediately
Analyte3(merged)concentration
Unclamped analyte 1 concentration value
0=do not adjust auto cal; 1=adjust auto cal
UserstandarddeviationinWIRfilter
System state 2. 100=NotReady,
201=MeasureRun,502=Idle,600=diag
Boolean,1=ATEX,0=normal
Analyte3(merged)concentration
Cross-overpointforAlyte3concentration