NetLinx Security with a Terminal Connection
128
NI-3101-SIG Signature Series NetLinx Integrated Controller
2. Select a group from the list of currently enrolled groups and press <Enter> to open the Edit Group
Menu. This is the same Edit Group Menu that was access via the Add Group option:
1) Add Directory Association
2) Delete Directory Association
3) List Directory Associations
4) Change Access Rights
5) Display Access Rights
Or <ENTER> to return to previous menu
Edit group ->
This menu is described on the previous pages (see Edit Group Menu section on page 125).
Option 9 - Delete Group
1.
Type 9 and <Enter> at the Security Setup prompt (at the bottom of the Main Security Menu) to
delete an existing group account. A sample session response is:
Select from the following list:
1) Group 1
2) Group 2
Select group ->
2. Select the group account to be deleted, and press <Enter> to delete the group and return to the
Security Setup menu.
Option 10 - Show List of Authorized Groups
1.
Type 10 and <Enter> at the Security Setup prompt (at the bottom of the Main Security Menu) to
display a list of all authorized group accounts. A sample session response is:
The following groups are currently enrolled:
administrator
Group 1
Press <ENTER> key to continue
2. Press <Enter> to return to the Security Setup Menu.
Option 11 - Set Telnet Timeout in seconds
This feature is disabled after the installation of firmware build 130 or higher onto your target Master.
1. Type 11 and <Enter> at the Security Setup prompt (at the bottom of the Main Security Menu) to set
the Telnet Timeout value, in seconds. A sample session response is:
Specify Telnet Timeout in seconds:
2. Enter the number of seconds before you want The Telnet session to timeout, and press <Enter> to
return to the Security Setup Menu.
Changes made to the target Master from within the Terminal window are not reflected
within the web browser, until the Master is rebooted and the web browser connection
is refreshed.
Any changes made to the Master, from within the web browser are instantly reflected
within the Terminal session without the need to reboot.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX NetLinx NI-3101-SIG and is the answer not in the manual?

AMX NetLinx NI-3101-SIG Specifications

General IconGeneral
BrandAMX
ModelNetLinx NI-3101-SIG
CategoryController
LanguageEnglish

Related product manuals