Programming
138
NI-3101-SIG Signature Series NetLinx Integrated Controller
Master Send_Commands (Cont.)
Command Description
G4WC
Add G4 Web Control devices
to Web control list displayed
by the Web server in a
browser.
The internal G4WC Send command (to Master 0:1:0) has been revised to add
G4 WebControl devices to Web control list displayed in the browser.
Syntax:
SEND_COMMAND <D:P:S>,"'G4WC "Name/Description",IP
Address/URL,IP Port,Enabled'"
Variables:
Name/Description = A string, enclosed in double quotes, that is the
description of the G4 Web Control instance. It is displayed in the browser.
IP Address/URL = A string containing the IP Address of the G4 Web Control
server, or a URL to the G4 Web Control server.
IP Port = A string containing the IP Port of the G4 Web Control Server.
Enabled = 1 or 0. If it is a 1 then the link is displayed. If it is a 0 then the link is
disabled.
The combination of Name/Description, IP Address/URL, and IP Port are
used to determine each unique listing.
Example:
SEND_COMMAND 0:1:0,"'G4WC "Bedroom",192.168.1.2,5900,1'"
Adds the BEDROOM control device using the IP Address of 192.168.1.2.
~IGNOREEXTERNAL-
CLOCKCOMMANDS
Set the Master so that it
cannot have it’s time set by
another device which
generates a ‘CLOCK’
command.
Syntax:
SEND_COMMAND <D:P:S>,"'~IGNOREEXTERNALCLOCKCOMMANDS'"
Example:
SEND_COMMAND 0:1:0,"'~IGNOREEXTERNALCLOCKCOMMANDS'"