NetLinx Security within the Web Server
50
NI-3101-SIG Signature Series NetLinx Integrated Controller
Requiring verification from a communicating AMX software (such as NetLinx Studio
v 2.4 or TPD4 v 2.5) before accepting communication for file/firmware transfers, the
Configuration, ICSP Connectivity and Require Encryption options must be enabled.
FIG. 34 System Level Security - Enable/Disable System Security page
System Level Security Page
Feature Description
Master Security: This option allows an authorized user to require that a valid
username and password be required for access to a feature
listed on this page.
These are global options that enable or disable the login
requirement for both users and groups.
If the Master Security checkbox is not enabled, all subordinate
options are greyed-out and not selectable, meaning that the
Master is completely unsecured and can be altered by any user
(regardless of their rights).
Terminal (RS232/USB) Access: This selection determines if a username and password is
required for Terminal communication (through the USB
connector).
If Terminal Security is enabled, a user must have sufficient
access rights to login to a Terminal session and communicate
with the Master.
HTTP Access: This selection determines if a username and password is
required for communication over HTTP or HTTPS Ports (see
FIG. 35).
If enabled, a user must have sufficient access rights to browse
to the NetLinx Master via a Web Browser.
Enabling this field requires the user (within a new session)
submit a valid username and password before being able
to view the web server pages.
If disabled, the Master is open for viewing and does not ask
for this information during any consecutive sessions (until
the user attempts to access a feature which is enabled
within this page).
This requirement of a valid username and password affects
both HTTP and HTTPS communication with the target
Master using the web server.
NetLinx Master
security features
Require Encryption
option (enable/disable)
Security Level features

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX NetLinx NI-3101-SIG and is the answer not in the manual?

AMX NetLinx NI-3101-SIG Specifications

General IconGeneral
BrandAMX
ModelNetLinx NI-3101-SIG
CategoryController
LanguageEnglish

Related product manuals