Programming
152
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
"^" Button Commands (Cont.)
^BPP Set or clear the protected page flip flag of a button.
Zero clears the flag.
Syntax:
"'^BPP-<vt addr range>,<protected page flip flag value>'"
Variables:
variable text address range = 1 - 4000.
protected page flip flag value range = 0 - 4 (0 clears the flag).
Example:
SEND_COMMAND Panel,"'^BPP-500,1'"
Sets the button to protected page flip flag 1 (sets it to password 1).
^BRD Set the border of a button state/states, only if the specified border is not the same as the
current border.
The border style is available through the TPDesign4 border-style drop-down list.
Refer to theTPD4 Border Styles by Name table on page 141 for more information.
Syntax:
"'^BRD-<vt addr range>,<button states range>,<border name>'"
Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
border name = Refer toBorder Styles and Programming Numbers table on page 140.
Example:
SEND_COMMAND Panel,"'^BRD-500.504&510.515,1&2,Quad Line'"
Sets the border by name (Quad Line) to those buttons with the variable text range of
500-504 & 510-515.
^BSF Set the focus to the text area.
Note: Select one button at a time (single variable text address).
Do not assign a variable text address range to set focus to multiple buttons.
Only one variable text address can be in focus at a time.
Syntax:
"'^BSF-<vt addr range>,<selection value>'"
Variables:
variable text address range = 1 - 4000.
selection value = Unselect = 0 and select = 1.
Example:
SEND_COMMAND Panel,"'^BSF-500,1'"
Sets the focus to the text area of the button.
^BSP Set the button size and its position on the page.
Syntax:
"'^BSP-<vt addr range>,<left>,<top>,<right>,<bottom>'"
Variable:
variable text address range = 1 - 4000.
left = left side of page.
top = top of page.
right = right side of page.
bottom = bottom of page.
Example:
SEND_COMMAND Panel,"'^BSP-530,left,top'"
Sets the button with variable text 530 in the left side top of page.