Programming
157
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
"^" Button Commands (Cont.)
^GSN Change the bargraph slider name or joystick cursor name.
Slider names and cursor names can be found in the TPDesign4 slider name and cursor
drop-down list.
Syntax:
"'^GSN-<vt addr range>,<bargraph slider name>'"
Variable:
variable text address range = 1 - 4000.
bargraph slider name = See table below.
Example:
SEND_COMMAND Panel,"'^GSN-500,Ball'"
Changes the bargraph slider name or the Joystick cursor name to ’Ball’.
^ICO Set the icon to a button.
Syntax:
"'^ICO-<vt addr range>,<button states range>,<icon index>'"
Variables:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
icon index range = 0 - 9900 (a value of 0 is clear).
Example:
SEND_COMMAND Panel,"'^ICO-500.504&510.515,1&2,1'"
Sets the icon for On and Off states for buttons with variable text ranges of 500-504 &
510-515.
Bargraph Slider Names:
Circle -M
None
Circle -S
Ball
Precision
Circle -L
Rectangle -L
Rectangle -M
Rectangle -S
Windows
Windows Active
Joystick Cursor Names:
Circle
None
Crosshairs
Arrow
Gunsight
Ball
Hand
Metal
Spiral
Target
View Finder