Operation/Reference Guide
Touch Panels
7” Modero Touch Panels
NXD-700i 7” Wall/Flush Mount Touch Panel with Intercom
NXT-CA7 7” Table Top Touch Panel
Last Revised: 9/30/2011

Table of Contents

Questions and Answers

  • L
    Lisa WoodAug 19, 2025
    How to fix AMX NXD-700i USB driver with yellow exclamation point?
    • K
      Kevin FranklinAug 19, 2025
      If your AMX Touch Panel USB driver shows a yellow exclamation point, it likely wasn't installed correctly. To reinstall it: * Disconnect the USB cable from the panel. * Connect the USB cable to the G4 panel; a USB icon should appear in the System Tray. * Double-click the icon to see the "AMX USB LAN LINK" device. * If the driver install dialog doesn't appear, select "Properties," then "Update Driver." * Click "Next" in the Install Driver dialog to accept defaults. Ignore any warnings about the digital signature and continue the installation. The exclamation point should disappear after installation.
  • D
    Dylan AyersAug 21, 2025
    Why is my AMX Modero Touch Panel not appearing in Workspace window?
    • J
      james57Aug 21, 2025
      If your AMX Modero Touch Panel isn’t showing up in the Workspace window, make sure that the System number is the same in both the NetLinx Workspace window and on the System Connection page of the Modero panel. Also, verify that you've correctly entered the NetLinx Master IP and connection methods in the Master Connection section of the System Connection page.
  • B
    Barbara JonesAug 23, 2025
    What to do if AMX NXD-700i communication icon doesn't turn green?
    • C
      Carla DayAug 25, 2025
      A green communication icon indicates a successful connection to the target Master or Virtual Master. Here’s how to troubleshoot if your AMX Touch Panel communication icon isn’t turning green: * Launch NetLinx Studio and configure the Master Connection communication settings for a Virtual Master. * Go to the System connection page and set the Type field to USB. * Ensure the Type-A USB connector is securely connected to the PC. * Disconnect the mini-USB from the panel and turn the panel OFF. * Turn the panel ON, then connect the mini-USB to the Program Port. The USB icon should appear in the system tray. If it doesn’t, refer to the Configuring and Using USB with a Virtual Master section on page 25 of the manual. * Allow the panel a few minutes to detect the connection to the PC.
  • M
    Mary TaylorAug 26, 2025
    Why AMX NXD-700i Connection Status button isn’t blinking?
    • D
      Dominic WilliamsAug 27, 2025
      If your AMX Touch Panel's Connection Status button isn't blinking and displays "USB Connecting", it means the panel is trying to establish USB communication. Try these steps: * Disconnect the USB connector from the panel and close all AMX applications. * Reboot the panel. * Restart the AMX application and try reconnecting to the panel. * If you're using Studio for Virtual Master communication, establish a Virtual Master connection, confirm the correct System number, stop communication with the Virtual Master, and then re-establish communication by refreshing the system. * After the panel restarts, reconnect the USB connector. * Check your System Tray for a valid USB connection.
  • S
    Samantha BennettAug 28, 2025
    What to do if AMX Modero Touch Panel can’t obtain a DHCP Address?
    • C
      Christopher MathewsAug 28, 2025
      If your AMX Modero Touch Panel isn't getting a DHCP address, keep in mind that it can take a few minutes for the DHCP Server to provide the address. Follow these steps: * Make sure an active Ethernet connection is connected to the back of the Modero before you start. * From the Main menu, go to Diagnostics > Network Address and check the System number. * If the IP Address field is still empty, wait a few minutes for the Modero to negotiate a DHCP Address and try again.
  • S
    Steven CampbellAug 30, 2025
    Why does a VNC Server dialog appear when using AMX G4 WebControl?
    • H
      hollowayalexAug 30, 2025
      When using G4 WebControl to connect to an AMX Touch Panel, a G4 Authentication dialog should appear, prompting you for the panel's password. If a VNC Server dialog appears instead, here's what to do: * Enter the IP Address of the target panel. You can find this within the Setup > Protected Setup > System Connection page, in the IP Settings section. * Click OK after entering the IP Address. * When the G4 Authentication popup appears, enter the panel’s WebControl password.
  • R
    Robert BowenSep 1, 2025
    What to do if AMX NXD-700i Touch Panel is not showing up in Virtual Master’s System list?
    • B
      Briana MitchellSep 1, 2025
      If your AMX Touch Panel isn't showing up in the Virtual Master's system list, it might be retaining information from a previous Virtual Master connection. Try these steps: * Reboot the panel without the USB cable connected. * Configure NetLinx Studio for a Virtual Master connection, noting the System Number used in the Edit Settings window. * Stop communication on the Virtual Master by going to Settings > Stop Communications and clicking Yes. * Select the System Number (from the Online Tree tab) and right-click to select Refresh System. This re-establishes communication with the Virtual Master. * Plug the mini-USB cable into the panel. * Wait a few seconds and refresh the system again. The panel should now appear in the list.
  • M
    Mr. Anthony MorrisonSep 4, 2025
    Why only one AMX Modero panel shows up when multiple are connected?
    • C
      Cheryl SimmonsSep 4, 2025
      If you have multiple Modero panels connected to your AMX System Master but only one is showing up, it's likely due to conflicting Device Number values. Here’s how to resolve it: * Press and hold the grey Front Setup Access button for 3 seconds to access the Setup page. * Press the Protected Setup button (lower-left of the panel), enter 1988 as the password, and press Done. * Enter a unique Device Number value for each panel. The default is 10001, and the range is 1-32000.
  • T
    Tanner ThompsonSep 6, 2025
    Why is calibration not working on my AMX Modero Touch Panel?
    • C
      Clayton GonzalezSep 6, 2025
      If calibration isn't working on your AMX Modero touch panel, it may need to be reset, especially after a firmware update. Cycling the power to the panel should provide a baseline calibration. Then, go to the Calibration page and reset the on-screen calibration.
  • L
    Laurie JonesSep 8, 2025
    Why can’t I connect to a NetLinx Master using AMX NetLinx Studio?
    • B
      Betty MillerSep 8, 2025
      If you're having trouble connecting to a NetLinx Master using NetLinx Studio, try this: * Go to Settings > Master Comm Settings > Communication Settings > Settings (for TCP/IP). * Uncheck the "Automatically Ping the Master Controller to ensure availability" box. Note that while pinging checks for Master availability, some networks or firewalls block pings, causing connection failures. Disabling this option will still attempt a connection, but it may take longer to recognize a failure. This adjustment might be necessary when the master controller is behind a firewall.

Summary

NXD-700 i - Installation

NXT-CA7 - Installation

Panel Calibration

Calibrating the Panel

Detailed instructions on how to perform panel calibration using the front bezel button.

Configuring Communication

Modero Setup and System Connection

Steps to configure panel setup and system connection parameters for communication.

Configuring and Using USB with a Virtual Master

Guides on setting up USB communication with a Virtual Master using NetLinx Studio.

Confirm and View Current AMX USB Device Connections

Methods to confirm and view active USB device connections on the PC via Device Manager.

Configuring a Wired Ethernet Connection

Guides on configuring Ethernet connection types for panel communication.

Upgrading Modero Firmware

Upgrading the Firmware via the USB port

Detailed steps for updating firmware using a USB connection to the PC.

Configure the panel for a USB Connection Type

Steps to set up the panel for USB communication by selecting the correct connection type.

Prepare NetLinx Studio for communication via the USB port

Instructions to prepare NetLinx Studio for communication with the panel via USB.

Configure an Ethernet Connection Type

Guides on configuring Ethernet connection types for panel communication.

Confirm and Upgrade the firmware via the USB port

Steps to verify and complete the firmware upgrade process via USB.

Setup Pages and Descriptions

Security Settings

Covers security settings like Standard, Secure, and DoD profiles for panel access and login.

System Settings Page

Details IP communication parameters, NetLinx Master settings, and device number assignments.

Calibrate Page

Explains how to calibrate the touch panel for maximum sensitivity and accuracy.

G4 Web Control Settings Page

Settings for enabling/disabling G4 Web Control for remote panel display and control.

SIP Settings Page

Establishes network settings for using the touch panel as an IP phone.

Programming

Intercom Commands

Commands for managing intercom calls, audio levels, and microphone mute states.

Troubleshooting

AMX NXD-700i Specifications

General IconGeneral
Display Size7 inches
ConnectivityEthernet, Wi-Fi
Ethernet10/100 Mbps
Wi-Fi802.11 b/g/n
Resolution800 x 480
Power SupplyPoE or 12VDC
MountingWall or Table

Related product manuals