EasyManua.ls Logo

AMX NXD-700i - Bop; Bor; Bpp

AMX NXD-700i
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
89
NXD-700i & NXT-CA7 7” Modero Touch Panels
"^" Button Commands (Cont.)
^BOP Set the button opacity. The button opacity can be specified as a decimal between 0 - 255,
where zero (0) is invisible and 255 is opaque, or as a HEX code, as used in the color
commands by preceding the HEX code with the # sign. In this case, #00 becomes invisible
and #FF becomes opaque.
If the opacity is set to zero (0), this does not make the button inactive, only invisible.
Syntax:
"'^BOP-<vt addr range>,<button states range>,<button opacity>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
button opacity = 0 (invisible) - 255 (opaque).
Example:
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,200'"
Example 2:
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,#C8'"
Both examples set the opacity of the buttons with the variable text range of 500-504 and
510-515 to 200.
^BOR Set a border to a specific border style associated with a border value for those
buttons with a defined address range. Refer to theBorder Styles and Programming
Numbers table on page 78 for more information.
Syntax:
"'^BOR-<vt addr range>,<border style name or border value>'"
Variable:
variable text address range = 1 - 4000.
border style name = Refer to the Border Styles and Programming Numbers table on
page 78.
border value = 0 - 41.
Examples:
SEND_COMMAND Panel,"'^BOR-500.504&510.515,10'"
Sets the border by number (#10) to those buttons with the variable text range of 500-504
& 510-515.
SEND_COMMAND Panel,"'^BOR-500.504&510,AMX Elite -M'"
Sets the border by name (AMX Elite) to those buttons with the variable text range of
500-504 & 510-515.
Note: The border style is available through the TPDesign4 border-style drop-down list.
Refer to theTPD4 Border Styles by Name table on page 79 for more information.
^BPP Set or clear the protected page flip flag of a button.
Zero clears the flag.
Syntax:
"'^BPP-<vt addr range>,<protected page flip flag value>'"
Variable:
variable text address range = 1 - 4000.
protected page flip flag value range = 0 - 4 (0 clears the flag).
Example:
SEND_COMMAND Panel,"'^BPP-500,1'"
Sets the button to protected page flip flag 1 (sets it to password 1).

Table of Contents