Programming
158
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
"^" Button Commands (Cont.)
^JSB Set bitmap/picture alignment using a numeric keypad layout for buttons with a defined
address range.
The alignment of 0 is followed by ',<left>,<top>'.
The left and top coordinates are relative to the upper left corner of the button.
Syntax:
"'^JSB-<vt addr range>,<button states range>,<new text alignment>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
new text alignment = Value of 1- 9 corresponds to the following locations:
Example:
SEND_COMMAND Panel,"'^JSB-500.504&510.515,1&2,1'"
Sets the off/on state picture alignment to upper left corner for those buttons with variable
text ranges of 500-504 & 510-515.
^JSI Set icon alignment using a numeric keypad layout for buttons with a defined address
range.
The alignment of 0 is followed by ',<left>,<top>'. The left and top coordinates are relative to
the upper left corner of the button.
Syntax:
"'^JSI-<vt addr range>,<button states range>,<new icon alignment>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
new icon alignment = Value of 1 - 9 corresponds to the following locations:
Example:
SEND_COMMAND Panel,"'^JSI-500.504&510.515,1&2,1'"
Sets the Off/On state icon alignment to upper left corner for those buttons with variable text