Programming
163
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom 
{
   SEND_STRING 0,"'ButtonGet Id=',ITOA(CUSTOM.ID),' Type=',ITOA(CUSTOM.TYPE)" 
   SEND_STRING 0,"'Flag   =',ITOA(CUSTOM.FLAG)"
   SEND_STRING 0,"'VALUE1 =',ITOA(CUSTOM.VALUE1)"
   SEND_STRING 0,"'VALUE2 =',ITOA(CUSTOM.VALUE2)"
   SEND_STRING 0,"'VALUE3 =',ITOA(CUSTOM.VALUE3)"
   SEND_STRING 0,"'TEXT   =',CUSTOM.TEXT"
   SEND_STRING 0,"'TEXT LENGTH =',ITOA(LENGTH_STRING(CUSTOM.TEXT))"
}
All custom events have the following 6 fields:      
These fields are populated differently for each query command. The text length (String Encode) field is not 
used in any command.     
Custom Event Fields
Field Description
Uint Flag 0 means text is a standard string, 1 means Unicode encoded string
slong value1 button state number
slong value2 actual length of string (this is not encoded size)
slong value3 index of first character (usually 1 or same as optional index
string text  the text from the button
text length (string encode) button text length
Button Query Commands
?BCB Get the current border color.
Syntax:
"'?BCB-<vt addr range>,<button states range>'"
Variables: 
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state). 
custom event type 1011:
   Flag   - zero
   Value1 - Button state number
   Value2 - Actual length of string (should be 9)
   Value3 - Zero
   Text   - Hex encoded color value (ex: #000000FF)
   Text length - Color name length (should be 9)
Example:
SEND COMMAND Panel,"'?BCB-529,1'"
Gets the button 'OFF state' border color. information. 
The result sent to the Master would be:
    ButtonGet Id = 529 Type = 1011
     Flag   = 0
     VALUE1 = 1
     VALUE2 = 9
     VALUE3 = 0
     TEXT   = #222222FF
     TEXT LENGTH = 9