Programming
180
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
Panel Setup Commands (Cont.)
^CFSM Sets the Flash cache to the maximum available size allowed for backup Flash cache.
Determined by taking 75% of free Flash space.
Syntax:
“’^CFSM’”
Variable: none
Example:
SEND_COMMAND Panel, “’^CFSM’”
Modifies the Flash cache size to the maximum available size for the device.
^CEX Changes the default expiration time for entries in the image cache (applies to both primary
RAM cache and backup Flash cache).
The default expiration time applies to dynamic images only.
Syntax:
“’^CEX-<time index>’”
Variable:
time index:
1 = 2 Hours
2 = 8 Hours
3 = 1 Day
4 = 2 Days
5 = 5 Days
0 = NEVER
Example:
SEND_COMMAND Panel, “’^CEX-4’”
Changes the default expiration time to 2 Days.
^DLD Set the disable cradle LED flag.
Syntax:
“’^DLD-<0/1>’”
Variables:
0 - LEDs operate normally
1 - Cradle LEDs operate dim setting only
Example:
SEND_COMMAND Panel, “’^DLD-1’”
Sets the cradle LEDs to the dim setting.
@PWD Set the page flip password.
This command sets the level 1 password only.
Syntax:
"'@PWD-<page flip password>'"
Variables:
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'@PWD-Main'"
Sets the page flip password to 'Main'.
^PWD Set the page flip password.
Password level is required and must be 1 - 4.
Syntax:
"'^PWD-<password level>,<page flip password>'"
Variables:
password level = 1 - 4.
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'^PWD-1,Main'"
Sets the page flip password on Password Level 1 to 'Main'.