Programming
180
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
Panel Setup Commands (Cont.)
^CFSM Sets the Flash cache to the maximum available size allowed for backup Flash cache.
• Determined by taking 75% of free Flash space.
Syntax:
“’^CFSM’”
Variable: none
Example:
SEND_COMMAND Panel, “’^CFSM’”
Modifies the Flash cache size to the maximum available size for the device.
^CEX Changes the default expiration time for entries in the image cache (applies to both primary
RAM cache and backup Flash cache).
• The default expiration time applies to dynamic images only.
Syntax:
“’^CEX-<time index>’”
Variable:
time index:
1 = 2 Hours
2 = 8 Hours
3 = 1 Day
4 = 2 Days
5 = 5 Days
0 = NEVER
Example:
SEND_COMMAND Panel, “’^CEX-4’”
Changes the default expiration time to 2 Days.
^DLD Set the disable cradle LED flag.
Syntax:
“’^DLD-<0/1>’”
Variables:
0 - LEDs operate normally
1 - Cradle LEDs operate dim setting only
Example:
SEND_COMMAND Panel, “’^DLD-1’”
Sets the cradle LEDs to the dim setting.
@PWD Set the page flip password.
• This command sets the level 1 password only.
Syntax:
"'@PWD-<page flip password>'"
Variables:
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'@PWD-Main'"
Sets the page flip password to 'Main'.
^PWD Set the page flip password.
Password level is required and must be 1 - 4.
Syntax:
"'^PWD-<password level>,<page flip password>'"
Variables:
password level = 1 - 4.
page flip password = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'^PWD-1,Main'"
Sets the page flip password on Password Level 1 to 'Main'.