Installation
29
NXD-1000Vi 10" Modero® Wall/Flush Mount Touch Panel with Intercom
3. Remove the Faceplate/bezel (A in FIG. 22) from the main NXD unit (B in FIG. 22) by gripping the
faceplate and pulling with gentle outward force.
4. Thread the incoming power, RJ-45, Ethernet, USB, and any optional audio/video wiring (from their
terminal locations) through the surface opening. Leave enough slack in the wiring to accommodate any
re-positioning of the panel.
5. Connect all data and power wiring connectors to their corresponding locations along the left side of the
(un-powered) NXD touch panel.
Verify that the terminal end of the power cable is not connected to a power source before plugging
in the 2-pin power connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.
FIG. 21 NXD-1000Vi Wall Mount panel dimensions using expansion clips