Use and installation manual
Alarm Fault Remedy Notes
H2O
No water in chamber, or water
pressure too low
Check that mains water is
present or adjust the pressure
(see page 29); if the problem
persists inform the after-sales
service
Convection cooking cycles can
still be carried out
H2O.
No water at drain, or water pres-
sure too low
Check that mains water is
present or adjust the pressure
(see page 29); if the problem
persists inform the after-sales
service
Convection and steam cooking
cycles can still be carried out
OPE
Oven door opening or closure
request
Open or close the oven door
Inform the after-sales service if
this message continues to be
displayed
The cooking cycle does not start
until the door has been opened
or closed as required
CLE
Indicates that cleaning is re-
quired
Clean
The oven's functions are ena-
bled so cooking cycles can be
carried out
E01
The cooking chamber probe
has failed or is not properly con-
nected
Inform the after-sales service
The oven's functions are disa-
bled so no cooking cycles can
be carried out
E02
The product core probe is not
inserted in the food or has failed
Check the position of the prod-
uct core probe or inform the af-
ter-sales service if it is faulty
Cooking cycles with product
core probe cannot be carried
out
E03
The steam discharge probe has
failed
Inform the after-sales service
Convection and steam cooking
cycles can still be carried out
E04
The motor-operated valve is not
positioned correctly
Switch on the oven again and if
the problem persists inform the
after-sales service
Convection and steam cooking
cycles can still be carried out
E05 Safety thermostat failure Inform the after-sales service
The oven's functions are disa-
bled so no cooking cycles can
be carried out
E06 Overload cutouts tripped Inform the after-sales service
The oven's functions are disa-
bled so no cooking cycles can
be carried out
E08
The optional vacuum probe has
failed or is not properly connect-
ed
Press the "Reset" button
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle.
If the problem persists, call the
after-sales service

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Angelo Po FX 101 E 1-2 and is the answer not in the manual?

Angelo Po FX 101 E 1-2 Specifications

General IconGeneral
BrandAngelo Po
ModelFX 101 E 1-2
CategoryOven
LanguageEnglish

Related product manuals