3.6. Explanation table
When a component is replaced you must perform the procedures indicated below -
attention: these procedures should be performed after replacement of the component and
in the order listed below.
ITEM REPLACED PROCEDURES TO FOLLOW
CPU board (1a)
Update parameters procedure (alignment of the
power board with the CPU) - only boards 2
nd
generation (after March 2014)
Oven configuration procedure
Gas setup procedure
Power board (2)
Update parameters procedure (alignment of the
power board with the CPU) - only boards 2
nd
generation (after March 2014)
Oven configuration procedure
Inverter (4)
Oven configuration procedure
Combustion and fan control
PCBs (3)
Oven configuration procedure
Note: After replacing one of the items listed above, at the first ignition of the oven you may
see alarms E13 and / or E20. After following the procedures listed in the table the alarms
should no longer appear.