Re turned
String: SENMM <s>,<mode>
SENSTL Set Sen sor Set tle Per cent age
SEN SOR
Syn tax: SENSTL <s>,<val>
s: A or B
val: 0.01 to 10%
Re marks: Sets how long the sys tem waits for the sig nal to set tle. The value pa ram -
e ter is only used in DE FAULT mea sure ment sen sor mode. The set tling
time al lows some con trol over the trade off be tween speed, and the ex -
tent to which a mea sure ment has set tled to its fi nal value.
Query: SENSTL? <s>
Re turned
String: SENSTL <s>,<mode>
SEN TYP Re turn sen sor in for ma tion
SEN SOR
Syn tax: SEN TYP <s>
s: A or B
Re marks: This com mand re turns in for ma tion on the se lected sen sor in string for -
mat: <sen sor type>,<sen sor se rial> .
For ex am ple: Dual Di ode, PBD16 .
SRCMOD Source Sweep Mode
SYSTEM
Syn tax: SRCMOD <mode>
mode: FREQ
POWER
Re marks: De ter mines whether the volt age sweep ap plied to the V/Ghz an a log in -
put on the rear panel is in ter preted as a fre quency or power sweep. The
x axis of the graph on the dis play will be la beled ap pro pri ately.
Query: SRCMOD?
Re turned
String: SRCMOD <mode>
6-72 ML2400A OM
ML24XXA NATIVE COMMANDS GPIB OPERATION