CHAPTER 4
OPERATING INSTRUCTIONS
Entire Contents Copyright 2004 by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
APS-3000P Series 4 - 9 OM-001-03000-00P-03.9
System Parameter Settings
APS-3000P front panel displays are used to present status, test data, and system
parameters. This is the normal mode of display during operation. A special operator-
selected mode (described below) is entered when using the front panel displays for
setting system parameters.
Entering the System Parameter Setting Mode
To enter the System Parameter Setting Mode, begin from the RESET (Standby) mode.
Press the SYSTEM (on the CURRENT display) button. The SYSTEM LED (above
the SYSTEM switch) lights up. System parameters are shown in the FREQUENCY
and VOLTAGE displays. The present status and values are shown in the CURRENT
display.
Press the VOLTAGE ︿ or buttons to select parameters for adjustment.
Press the CURRENT ︿ or buttons to set status and values for each item.
Sequence of System Parameters
The System Parameter items are presented in the following order:
PLC Remote
GPIB Address (NOTE: Optional, only displays when installed)
Auto Voltage Adjust
Power-Up
Unit Testing Time
Auto Loop Cycle Ratio
Frequency Hi-Limit
Frequency Low-Limit
Voltage Hi-Limit
Voltage Low-Limit
Over-Current Foldback
After the last item appears, the system will cycle back to the first item on the list. When
you have finished, press SYSTEM (on the CURRENT Display), to exit the System
Parameter Setting mode.