CHAPTER 4
OPERATING INSTRUCTIONS
Entire Contents Copyright 2004 by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
APS-3000P Series 4 - 14 OM-001-03000-00P-03.9
Program Parameter Settings
When the system is in RESET (Standby) mode, press the PROGRAM button to enter
the Program Parameter setting mode. The PROGRAM parameter items are shown in
VOLTAGE display. The present status and values are shown in the CURRENT display
Press the VOLTAGE ︿ or ﹀ buttons to select items for adjustment.
Press the VOLTAGE ﹀ button to move to the next parameter item on the list.
Press the CURRENT ︿ or ﹀ buttons to set the status and values for each item.
The Program Parameter items are presented in the following order:
Program Selection
Manual / AutoRUN Mode Selection
Auto Loop Cycle
Step Selection
Output Voltage
Output Frequency
Testing Time
Delay Decision Time
Current High Limit
Current Low Limit
Power High Limit
Power Low Limit
Power Factor High Limit
Power Factor Low Limit
Connect Step
After the last item appears, the system will cycle back to the first item on the list. When
you have finished, press PROGRAM (on the CURRENT Display), to leave the
Program Parameter Setting mode.