40
MMA mode
No. Function parameters Default
Setting
range
Unit Description
P1
Background parameters
initialization
0 0/1 -
Restore factory default
(Select “1” to restore factory default)
P2 Welding time calculation 0.0 0.0~999 day Calculate welding time
P3 VRD switch at MMA 0 0/1 -
VRD switch at MMA
( “0”: VRD is off, “1”:VRD is on)
P4 Arc-force current at MMA 50 20
~
80 A
Given current value when output voltage
is below 14V at MMA
P5 Arc ignition current at MMA 60 20~100 A
Given current value of arc ignition at
MMA
P6 Arc ignition time at MMA 400 300
~
999 ms
Duration for given current value of arc
ignition at MMA
TIG mode
No. Function parameters Default
Setting
range
Unit Description
P1
Background parameters
initialization
0 0/1 -
Restore factory default
(Select “1” to restore factory default)
P2 Welding time calculation 0.0 0.0
~
999 day Calculate welding time
P3 Lift TIG current 50 35
~
65 A
Current value when tungsten and
workpiece are shorted at Lift TIG
P4 Post-flow time at TIG* 2.0 1.0-10.0 S Post-flow time at TIG
10.
MIG Basic Welding Technique
! WARINING BEWARE OF ELECTRIC SHOCK!
NOTICE: The following steps require applying power to the Welder
with the cover open.
To prevent serious injury from fire or electric shock:
1.DO NOT touch anything, especially not the ground clamp, with the
gun or welding wire or an arc will be ignited.
2. DO NOT touch internal Welder Components while it is plugged in.
https://www.arccaptain.com/