Absolute maximum heating
power
Maximum heating power
(heating absolute maximum
power percentage) (%)
Select of heating delay manage
0: manual (set with par. 2 36)
1: automatic (with Auto function working)
Heating delay (min), enabled by
par. 2 35= 0
Heating post-circulation (min)
Pump modulation on heating
0: speed 2 steady
1: speed 3 steady
2: modulating
ΔT for pump modulation (°C)
0 ÷ 60
(with Auto function working)
Heating water pressure
detection device
0: temperature probes only
1: pressure switch
2: pressure sensor
Sanitary comfort function
0: disabled
1: enabled for 30 minutes after a
heating request
2: always enabled
Sanitary delay start
(anti water hammering) (dec)
Sanitary switch off logic
0: anti-scale (62 o 65°C).
1: set-point+4°C
Sanitary post-circulation and
post-ventilation
0: Post-ventilation: Tflow<75°C = no post-
ventilation; Tflow>75°C = 3 min (minimum
speed); Post-circulation: 30sec
1: Post-ventilation: 3min
Post-circulation: 3min
Heating start delay after sanitary
(min)
Reset menu 2 factory setting
YES: press button “MENU’/OK”
NO: press button “ESC”