Training manual CLAS
Pag. 58 di 71
6.3.2 Description of the programs on MENU 2: BOILER PARAMETERS
6. To modify the parameter
selected press button
“MENU/OK” and then
with pushbuttons “+” and
-“ you can change the
value.
7. To memorize the
parameter change press
button “MENU/OK”
8. To exit from menu
press button “ESC”
Menu
Sub
-Menu
Parameter
Operation
Regulating range
Default
value
2
1
ACCESS CODE
With button “+” or “-“ set: 2 3 4
222
2
2
BOILER GENERAL SETTING
2
2
0
Slow ignition as % of the
maximum heating power
0 ÷ 99
See
paragraph
5.3.9
2
2
1
Minimum temperature for
antifreeze activation (°C)
2 ÷ 10
2
2
5
Heating delay restart
0: disabled
1: 10 seconds
2: 90 seconds
3: 210 seconds
0
2
2
8
Boiler version
0: combi
1: tank
2: only heating or system
3: micro-storage
4: internal stratification tank
5: internal standard tank
0
follows