EasyManua.ls Logo

Ariston CLAS - Page 66

Ariston CLAS
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Training manual CLAS
Pag. 66 di 71
ELECTRONIC CARD
3 01
Eeprom display error
No Reset
3 02
GP GIU communication error
No Reset
3 03
PCB internal error
No Reset
3 04
More than 5 resets executed in 15 minutes
No Reset
3 05
PCB internal error
Reset
3 06
PCB card internal error
Reset
3 07
PCB card internal error
Reset
COMMUNICATION WITH PERIPHERALS
4 01
Communication error between modem and BUS
No Reset
4 02
Modem error GPRS/GSM
No Reset
4 03
Sim Card modem error
No Reset
4 04
Communication error between modem and card
No Reset
4 05
Modem error
No Reset
4 06
Modem error
No Reset
4 07
Room probe open or short circuit
No Reset
IGNITION AND DETECTION
5 01
Flame missing
Reset
5 02
Flame detected with gas valve closed
No Reset
5 P3
Flame detachment during operation
Signalling
AIR INLET / FUME OUTLET
6 01
Fume thermostat enabling (only on open chamber)
No Reset
6 02
Fume thermostat enabling (only on open chamber
VMC)
Reset
6 07
Air pressure switch enabled before ignition sequence
No Reset
6 P1
Air pressure switch closing delayed
No Reset
6 P2
Air pressure switch opening during burner on
No Reset
ZONES
7 01
Heating delivery probe zone 2 open or short circuit
No Reset
7 02
Heating return probe zone 2 open or short circuit
No Reset
7 03
Heating delivery probe zone 3 open or short circuit
No Reset
7 04
Heating return probe zone 3 open or short circuit
No Reset
7 05
Hydraulic separator probe open or short circuit
No Reset
7 06
Zone 2 overheating
No Reset
7 07
Zone 3 overheating
No Reset

Table of Contents