ITS101 Installation Manual
6. Technical specifications
6.1. Electrical specifications
Power Requirements
Supply voltage Min. Typ. Max.
+10 V DC +12 V DC +14 V DC
Power consumption with
ITS101-CAM
- 7W (0.6A) 10W (0.8A)
Power consumption with
external Analog ANPR
camera (CVBS Input)
3.6W (0.3A) 5W (0.4A)
Table 6: Power requirements for the ITS101
Interface Description Connector Remarks
POWER Power inlet 3-pin 45º screw Terminal Block
RELAY 2 relay outputs 6-pin 45º screw Terminal Block 30 V, 1 A
max.
2x RS-232 115 kbps RS-232 port 6-pin 45º screw Terminal Block
GPIO 2 digital inputs, isolated
2 digital outputs, isolated
6-pin 45º screw Terminal Block
ETHERNET 10/100 Mbps RJ45
ANPR Digital
Interface
ARVOO proprietary interface RJ45
ANPR CVBS
INPUT
PAL/NTSC video input, 75 Ω BNC, female
VIDEO OUTPUT
CVBS
PAL/NTSC video output, 75 Ω BNC, female
USB USB, low & full speed USB Not in use
Back To Default Back to default switch Switch
HW_RESET Hardware Reset, the same as
reboot by turning off/on the
power.
Switch
Table 7: Interface description of the ITS101.
ARVOO Imaging Products B.V. page 26 of 33