TD 92674EN
29 April 2015 / Ver. I
Configuration Manual
Ascom d81 DECT Handset
39
5. Handset Configuration
This configuration lets the user long press the push-button to dial the number without
sending an alarm. However, the push-button can be configured to send an alarm by pressing
it twice (see Alarm type for multiple press in chapter 5.27 Push Button Alarm on page 37).
5.28 Pull-Cord Alarm
Note: Pull-cord alarm is not available when upgrading the product license from d81
Messenger to d81 Protector. That is, only applicable for d81 Protector with the No-
movement/Man-down hardware. In addition, this function requires a functionality license.
see 4.4 Upgrade Handset by License on page 11.
The handset can be configured to send an alarm when the pull-cord is pulled off the
handset.
In a template or Number in PDM/Device Manager, the parameters for activation are found
at:
Alarm > Pull-cord alarm
The alarm can also be activated in the handset, see handset’s User Manual,.
Parameters in the current version are:
• Pull-cord alarm
•ALS
• Mode for automatic call after alarm
See also 5.26 Common Alarm Settings on page 37 for additional parameter settings.
Information about the handset’s location can also be sent along with an alarm, see 5.21
Base Station Location on page 32 and 5.22 DECT Location and LF Location on page 33.
5.29 Man-Down Alarm and No-Movement Alarm
NOTE: Man-down and No-movement are not available when upgrading the product license
from d81 Messenger to d81 Protector. That is, only applicable for d81 Protector with
the No-movement and Man-down hardware.
Man-down alarm: If the handset is tilted 45 degrees
1
(default) or more for a preset time
(default 7 seconds), the Man-down alarm is triggered.
No-movement alarm: If no movement is detected during a preset time (default 30 seconds),
the No-movement alarm is triggered.
The parameters for activation are found at:
Alarm > Man-down and No-movement alarm
The alarms can also be activated in the handset, see the handset’s User Manual.
Parameters in the current version are:
• Man-down alarm
Determines if the Man-down alarm is enabled or disabled.
• Man-down detection time
Determines when the warning phase starts after man-down is triggered.
1.The accuracy is +/- 10 degrees.