Configuration Manual
Ascom d81 DECT Handset
37
5. Handset Configuration
5.26 Common Alarm Settings
NOTE: This feature is applicable for d81 Protector only.
The parameters described in this chapter are applicable for all alarm types. See also 5.27
Push Button Alarm, 5.28 Pull-Cord Alarm, and 5.29 Man-Down Alarm and No-Movement
Alarm for additional parameter settings.
In a template or Number in PDM/Device Manager, the parameters for activation are found
at:
Alarm > Common
Parameters in the current version are:
• Stored alarm data
Information that is sent with an alarm (for example a handset location)
• Indicate triggered alarm with LED
1
• Indicate triggered alarm with vibrator
1
• Indicate triggered alarm with beeper signal
1
• Password protect ALS
Determines if a password is required to turn off the ALS
• Number for automatic call after alarm
Determines which number the handset automatically shall call after an alarm is sent. This
number can also be dialed without sending an alarm, see
5.27.1 Call Predefined Number
Without Sending Alarm on page 38.
• Volume for warning phase alert
Determines the volume of the warning phase tone for Man-down and No-movement.
5.27 Push Button Alarm
NOTE: This feature is applicable for d81 Protector only.
The way alarms are handled in a system can be configured. An alarm can be activated by a
user in two different ways:
• A single long press
• Multiple press
The following alarm types are handled:
• Push-button alarm
• Test alarm
In a template or Number in PDM/Device Manager, the parameters for activation are found
at:
Alarm > Alarm on long press
Alarm > Alarm on multiple press
Parameters in the current version are:
1. If the parameter "Silent alarm" is set, no indication is shown when an alarm has been sent or received.