Ascon Tecnologic - X34 - OPERATING INSTRUCTIONS - PAG. 25
]cl Group - Real Time Clock (RTC) setting parameters
Parameter Description Range Def. Note
96
c.CL (#)
Current time and current day of the week
h Hour
n Minute
d Day of the week (d.1 = Monday ... d.7 = Sunday)
d.oF Clock disabled
97
c.dt (#)
Current date
y Year
M Month
d Day date
]ce Group - Clock programmable events parameters
Parameter Description Range Def. Note
98
c.01 (#)
Event 1
h Hour
n Minute
d Day of the week (d.1 = Monday... d.7 = Sunday
d. 8 Every day
d. 9 From Monday to Friday
d.10 From Monday to Saturday
d.11 Saturday and Sunday
d.oF No day (event disabled)
t Event type
t.1 Switch ON
t.2 Stand-by
t.3 Switch ON Aux output
t.4 Switch OFF Aux output
t.5 Start defrost
t.6 Switch to Eco mode (SPE)
t.7 Switch to normal mode (SP)
h.0
n.0
d.oF
t.oF
99
c.02 (#)
Event 2
100
c.03 (#)
Event 3
101
c.04 (#)
Event 4
102
c.05 (#)
Event 5
103
c.06 (#)
Event 6
104
c.07 (#)
Event 7
105
c.08 (#)
Event 8
106
c.09 (#)
Event 9
107
c.10 (#)
Event 10
108
c.11 (#)
Event 11
109
c.12 (#)
Event 12
110
c.13 (#)
Event 13
111
c.14 (#)
Event 14
]Ha Group - HACCP stored alarms (read only parameters)
Parameter Description Range Def. Note
112
H.01 (#)
Stored Alarm no. 1
A. Alarm type (H1/L1/H2/L2/bo/AL)
y. Start year (10 ÷ 99)
M. Start month (1 ÷ 12)
d. Start date (1 ÷ 31)
h. Start hour (0 ÷ 23)
n. Start min. (0 ÷ 59)
E. Duration (0 ÷ 99 h)
e. Duration (0 ÷ 59 min)
_ Peak max./min. (critical temperature)
(-9.9 ÷ 999 °C/°F)
113
H.02 (#)
Stored Alarm no. 2
114
H.03 (#)
Stored Alarm no. 3
115
H.04 (#)
Stored Alarm no. 4
116
H.05 (#)
Stored Alarm no. 5
117
H.06 (#)
Stored Alarm no. 6
118
H.07 (#)
Stored Alarm no. 7
119
H.08 (#)
Stored Alarm no. 8
120
H.09 (#)
Stored Alarm no. 9
121
H.10 (#)
Stored Alarm no. 10
122
H.09 (#)
Number of HACCP alarms deleted (out of space) 0 ÷ 100 0