AC08 and AC12 Operations Manual....
39
8.3 STATUS WORD, cont.
INV TST OK Inverter tests OK. Proper switching action taking place in power stages.
Does not mean output voltage is correct yet. A “1” when operating.
PFC ENABLE The PFC stages have been enabled by the logic. Is a “0’ when the system is
off, turns to “1” at the end of the “walk-in” stage.
PFC TST OK The PFC tests OK when a “1” is indicated. The PFC ENABLE bit (see
above) must be set to “1” first.
SP1_OK Shore power #1 is acceptable for use by the system when a “1” is indicated.
Voltage only is checked, not frequency.
V OUT OK Hardware has determined that the output voltages are acceptable for use
when a “1” is indicated. Frequency is not checked.
INV OT Inverter or Power Supply (PFC) has over-temped and has caused a shutdown.
Should normally be a “0.”
PFC OT Incorporated into the INV OT bit (see above).
XFMR OT Not used at this time. Reserved for transformer over-temp.
SPARE Spare
SP1 LOW The logic has determined the shore power input is in the low range, 180-
260VAC when a “1” is indicated. Used for voltage range control relay.
K1 ENABLED Should indicate a “1” when the system is in the walk-in state, for
approximately 1 second after the start of the inverter start sequence.
K3 ENABLED The output contactor has been commanded to close when a “1” is indicated.
The inverter voltage must be in an acceptable range and the ships power
button is pressed.