Asiga MAX User Guide
Copyright ASIGA © 2017 VERSION 1.04
11. Gently push the build platform flat against the glass exposure plate. Ensure that the
edges of the build platform are not resting on the metal rim around the glass
exposure plate.
12. While still applying pressure, tighten the calibration screw with the 4mm hex key.
NOTE: to prevent slippage of the joint you should apply significant manual
force when tightening the calibration screw.
13. Click “Done”
14. Detect the zero position. The feedback from the position encoders may be used to
automatically detect the zero position of the build platform. To run the automatic
detection process, click “yes”.
15. The following screen will be displayed: