3. Place a finger on the underside of the vat film at a corner of the cured rectangle.
Your finger will provide support for the next step.
4. Use a piece of cardboard or plastic film to slide under the edge of the cured
rectangle and lift it off the Teflon film.
5. Remove the cured rectangle in one piece and dispose of it.
Set the Chamber Temperature
The MAX is equipped with an internal temperature controller which regulates the
temperature of the build chamber. Temperature control is useful when building with some
materials to control their viscosity, reactivity and solidification.
The chamber temperature can be set for when:
1. The machine is idle (i.e. not building any parts)