LCD 2 Cause Action
Overflow, Over Flow, Överfyllnad,
Overfyldning, Overfylling, Ylitulviminen,
Trop-plein, Reservoir legen, Traboc-
camento, Desbordamiento, Пeрeлив
вoды, Überfüllt
A micro switch, opening, for
detection of full, condensing water
container. Detection shall start 30
sec after a program is started. If
the micro switch is opened > 30
sec the program cycle should be
stopped and cleared.
Check if the customer has:
• Emptied the tank and restarted the machine
Service action:
• Clean hoses and check voltage and resistance in the drain
pump.
Check that the float has not got “stuck” and check
the function of the micro-switch.
Max Program Time, Max program
time , Maximal programtid, Maksimal
programtid, Maks programtid, Max
ohjelma-aika, Due maxi prog., Tijd
overschreden, Tempo max. progr.,
Duración máx prog, Пpeвышeниe
вpeмeни,, Max. Programmzeit
The cycle time exceeds 200
minutes. The cycle interupts and
the program is cleared.
High ambient temperature combi-
ned with low element output and
low drying temperature leads to
condensation formation.
Poor condensation due to blocked
external air
Check if the customer has:
• Tried spinning at a higher speed
• Has the machine switched off for 30 minutes before
restarting
• Good ventilation in the room
Service action:
• Ensure that the external air has free passage.
Thermistor fault, Thermistor Fault,
Thermistor fault, Termistorfel, Ter-
mostat fejl, Termistor, Termistorivika,
Défaut , Termistorfehler, Termistore ,
Fallo , Teрмист, Temp. sensor fout
1) The circuit for the thermistor
is open.
2) The thermistor is faulty
Service action:
Check the thermistors function. If needed, replace it.
Clean condenser, Rengör kondensor,
Rens kon.sator, Rens kon.sator, Puhdista
lauhdutin, Nettoyage condenseur,
Reinigen kondensor, Pulizia condensa-
tore, Limpiar condensador, Oчистить
кoндeнсaт, Kondenser reinigen
1) Indicated for each 100 cycle.
2) Indicated if the machine has in-
dicated ”Clean lint filter” 2 times.
Check if the customer has:
• Cleaned the condensor and filter
• Cleaned other air ducts
Clean Lint Filter, Clean Lint Filter,
Rengör filtret, Rengør fnugfilter, Rens
filter, Puhdista sihti, Nettoyage filtre,
Reinig filter, Pulizia filtro, Limpie el filtro,
Oчистить фильтp, Sieb reinigen
Indicated when air circulation and
temperature are incorrect
Check if the customer has:
• Cleaned the filter
After carrying out corrective actions as above, reset the fault indications by switching off the machine using the main