Servicemanual TD60
25
Fault indications TD60.1
Error messages panel type 1
Indication Cause Action
F1 flashes on the
display
• The condensation water tank is
full.
Empty the container and restart the machine.
F2 flashes on the
display
• Maximum permitted programme
time reached.
Empty the condensed water container and check that neither the fluff filter
nor the condenser are clogged.
Overly long drying times may also be due to the tumble dryer being located in
a confined area or room that is too small, causing the air to become too hot.
Make sure that the tumble dryer has access to more cold air, e.g. by opening
doors and/or windows.
Error messages panel type 2
Indication
Cause Action
The light to the
left of the start
button flashes
• The condensation water tank is
full.
Empty the container and restart the machine.
The light above
the start button
flashes
• Maximum permitted programme
time reached.
Empty the condensed water container and check that neither the fluff filter
nor the condenser are clogged.
Overly long drying times may also be due to the tumble dryer being located in
a confined area or room that is too small, causing the air to become too hot.
Make sure that the tumble dryer has access to more cold air, e.g. by opening
doors and/or windows.