Servicemanual TD60
24
Fault indications TD60.2
Error messages
Cause Action
Over flow
• A micro switch, opening,for
detection of full, condensing water
container. Detection shall
start 30 sec after a program is
started. If the micro switch is
opened > 30 sec the program
cycle should be stopped and
cleared.
• Check if the customer has Emptied the tank and restarted the machine
• Clean hoses and check voltage and resistance in the drain pump.
• Check that the float has not got “stuck” and check the function of the
micro-switch.
Max program
time
• The cycle time exceeds 200
minutes. The cycle interupts and
the program is cleared.
• High ambient temperature
combined with low element
output and low drying
temperature leads to
condensation formation.
• Poor condensation due to
blocked external air
Check if the customer has:
• Tried spinning at a higher speed.
• Has the machine switched off for 30 minutes before restarting
• Good ventilation in the room
• Ensure that the external air has free passage.
Clean lint filter
• Indicated when air circulation and
temperature are inccorect.
Clean condensor
•Indicated for each 100 cycle
• Indicated if the machine has indi-
cated ”Clean lint filter” 2 times.
• Clean the condensor and filter
• Clean other air ducts
Thermistor fault
• The circuit for the thermistor
is open.
• The thermistor is faulty
• Check the thermistors function. If needed, replace it.
Press stop button to exit fault indications