Servicemanual TD60
27
Total reset TD60.3
By pressing STOP (S3) + MAIN POWER SWITCH when power on the machine shall total reset.
All settings is returned to default values).
Heater 2 activation TD60.3
Heater 2 can be programd active or inactive.
Do the following:
1. Press STOP (S3) + MAIN POWER SWITCH
2. Press STOP (S3) five times (within 10 sec.)
3. Turn the Program selector (J1), choose ”Heater 2 On” or ”Heater 2 Off”.
Press the Program selector (S1) to store the settings.
Total reset TD60.2
By pressing STOP (S9) + MAIN POWER SWITCH when power on the machine shall total reset.
All settings is returned to default values)
Heater 2 activation TD60.2
Heating element 2 can be activated/deactivated by programming the machine.
• Turn off the machine using the main power switch.
• Press and hold -/+ button and the button for temperature and turn on the main power switch
• Turn the Program selector, choose ”Heater 2 On” or ”Heater 2 Off
• Press the start button to store the settings
Total reset TD60.1
A total reset is achieved by pressing the stop button when the machine is on. All settings are
restored to their default values.
Activating heating element 2 TD60.1
Heating element 2 can be activated/deactivated by programming the machine.
• Turn off the machine using the main power switch.
• Press and hold the Anti-crease button and turn on the main power switch. This opens the menu
for activating/deactivating heating element 2.
• Press the Time save button to activate/deactivate the heating element. When the heating ele-
ment is deactivated, the lights for Normal dry and Iron dry flash in sync. When the heating ele-
ment is activated, the lights for Normal dry, Iron dry and temperature flash in sync.
• Press the Stop button to save and exit the menu for activating/deactivating heating element 2.