EasyManua.ls Logo

Atlantic 024306 - Commissioning Technical Datasheet

Atlantic 024306
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 86 -
Commissioning technical datasheet
Site Installer
Outdoor unit
Serial No.
Hydraulic unit
Serial No.
Model Model
Refrigerant type Refrigerant load kg
Checks Operating voltage & current on outdoor unit
Compliance with positioning distances L/N V
Condensate evacuation correct L/E V
Electric connections / connections tightness N/E V
No GAS leaks (unit ID No.: ) Icomp A
Installation refrigeration connection correct (length m)
Taken in operation when HOT
Compressor discharge temperature °C
Liquid line temp. °C
}
}
}
Condensation
temperature
HP = bar °C Under-cooling °C
Tank water output temperature °C ΔCondensation Temp. °C
Tank water input temperature °C ΔSecondary Temp. °C
Evaporation temperature LP = bar °C
}
}
}
Suction Temp. °C Overheating °C
Battery air input temperature °C ΔEvaporation Temp. °C
Battery air output temperature °C ΔBattery Temp. °C
Hydraulic network on hydraulic unit
Secondary system
Under oor heating
system
}
Circulation pump brand Type
LT Radiators
Fan coils
Domestic hot water; tank type
Estimated water volume of secondary system L
Options & accessories
Power supply for electric backup Room sensor A59
Correct location of room sensor Wireless room sensor A75
2 circuit kit Wireless room sensor A78
Boiler connection kit
DetailsCooling kit
Control settings
Con guration type
Essential settings
Alfea Extensa A.I. R32 / INSTALLATION / 2114 - EN