Air/water heat pump
split 2 services
Outdoor unit Hydraulic unit
WOYA 060 LFCA 024122
WOYA 080 LFCA 024123
WOYA 100 LFTA

Table of Contents

Questions and Answers

  • H
    hannah21Aug 20, 2025
    How to fix low hydraulic flow rate in Atlantic 024122 Heat Pump?
    • R
      Ryan SellersAug 20, 2025
      If the hydraulic flow rate is too low in your Atlantic Heat Pump, it might be due to circulation pump speed settings being too low or a clogged filter valve. You should check and adjust the circulation pump speed settings or clean the clogged filter valve.
  • D
    dhayesAug 22, 2025
    Why is the hydraulic flow rate low in my Atlantic 024122 Heat Pump?
    • C
      Christopher HutchinsonAug 22, 2025
      If you're experiencing a low hydraulic flow rate in your Atlantic Heat Pump, it could be due to circulation pump speed settings being too low or a clogged filter valve. You should check and adjust the circulation pump speed settings, or clean the clogged filter valve.
  • G
    Gina ChavezAug 25, 2025
    What to do if initial or return temperature is too low in Atlantic 024122?
    • B
      Bethany WallaceAug 25, 2025
      If the initial temperature (T5) or return temperature (T6) is less than 2°C in your Atlantic Heat Pump, it could be due to a defective frost protection function or a disconnected back-up. Check and repair the frost protection function, or reconnect the back-up.
  • S
    sherrymccarthyAug 26, 2025
    Why is DHW cycle too long in Atlantic 024122 Heat Pump?
    • A
      Ashley BarryAug 27, 2025
      If the DHW cycle is too long (more than 6 hours) in your Atlantic Heat Pump, it may be because of too much draw-off during the same cycle or a disconnected DHW back-up. Reduce the draw-off during the DHW cycle or reconnect the DHW back-up.
  • N
    Nicholas SalazarAug 27, 2025
    What causes frost on return circuit during defrost in Atlantic 024122?
    • W
      Willie HamiltonAug 28, 2025
      If frost is detected on the return circuit when defrosting the outdoor unit (temperature < 2°C) in your Atlantic Heat Pump, the circulating water volume may be too low. Increase the circulating water volume.
  • D
    Dr. Matthew ThomasAug 29, 2025
    How to fix communication error in Atlantic 024122 Heat Pump?
    • J
      james36Aug 29, 2025
      If you're experiencing a communication error between the interface board and the HP regulator board in your Atlantic Heat Pump, check the wiring by inspecting and securing the wiring connections.
  • A
    Ashley FlemingAug 31, 2025
    What to do if there is legionella cycle error in Atlantic 024122 Heat Pump?
    • C
      Chelsea MillerAug 31, 2025
      If you encounter a Legionella cycle error in your Atlantic Heat Pump, it might be due to a disconnected DHW back-up. Reconnect the DHW back-up.
  • J
    Jonathan AlexanderSep 2, 2025
    How to troubleshoot HP outgoing flow sensor error (T5) in Atlantic 024122 Heat Pump?
    • C
      Carmen LinSep 2, 2025
      If there's an error with the HP outgoing flow sensor (T5) in your Atlantic Heat Pump, it could be due to a short circuit, disconnected or cut off sensor, a defective sensor, or another error. Check the sensor connections or replace the defective sensor.
  • L
    lauren85Sep 4, 2025
    How to troubleshoot HP return flow sensor error (T6) in Atlantic 024122 Heat Pump?
    • N
      Nathan HallSep 4, 2025
      If there's an error with the HP return flow sensor (T6) in your Atlantic Heat Pump, it could be due to a short circuit, disconnected or cut off sensor, a defective sensor, or another error. Check the sensor connections or replace the defective sensor.
  • A
    Alex RomeroSep 6, 2025
    What causes outdoor temperature sensor error (T7) in Atlantic Heat Pump?
    • E
      ernest65Sep 6, 2025
      If there's an error with the outdoor temperature sensor (T7) in your Atlantic Heat Pump, it could be due to a short circuit, disconnected or cut off sensor, a defective sensor, or another error. Check the sensor connections or replace the defective sensor.